9.4 Set and Save Data Lock
Syntax
Hexadecimal 0xFE 0xCB 0xF5 0xA0 [level]
Decimal 254 203 245 160 [level]
Parameters
Parameter Length Description
level 1 Sets the data lock level
Description This command will set and save the data lock level. See the Data Lock
section for more information.
Remembered Always
Default 0
9.5 Write Customer Data
Syntax
Hexadecimal 0xFE 0x34 [data]
Decimal 254 52 [data]
ASCII 254 “4” [data]
Parameters
Parameter Length Description
data 16 Writes the customer data
Description Writes the customer Data. 16 Bytes of data can be saved in non-volatile
memory.
Remembered No
9.6 Read Customer Data
Syntax
Hexadecimal 0xFE 0x35
Decimal 254 53
ASCII 254 “5”
Description Reads whatever was written by Write Customer Data.
Remembered No
10 Miscellaneous
10.1 Introduction
This chapter covers the Report Version Number’ and ’Read Module Type’ commands. These commands
can be particularly useful to find out more information about the display module before contacting technical
support.